Recovering Clock from PSTN Line Interface
                                            This section provides a brief description for configuring synchronization based on recovering clock from the PSTN line interface. For a full description of the clock parameters, see PSTN Parameters.
                                            
                                                
                                                
                                                
                                                
                                                    |  | ➢ | To configure synchronization based on clock from PSTN line: | 
                                            
                                            
                                                
                                                
                                                
                                                
                                                    |  | 1. | Open the TDM Bus Settings page (Setup menu > Signaling & Media tab > Gateway folder > TDM Bus Settings). | 
                                            
                                            
                                                 
                                            
                                            
                                                
                                                
                                                
                                                
                                                    |  | a. | From the 'TDM Bus Clock Source' drop-down list (TDMBusClockSource), select Network to recover the clock from the line interface. | 
                                            
                                            
                                                
                                                
                                                
                                                
                                                    |  | b. | In the 'TDM Bus Local Reference' field (TDMBusLocalReference), enter the trunk from which the clock is derived. | 
                                            
                                            
                                                
                                                    
                                                    
                                                    
                                                    
                                                        |  | ● | The E1/T1 trunk should recover the clock from the remote side (see below description of the 'Clock Master' parameter). | 
                                                
                                             
                                            
                                                
                                                
                                                
                                                
                                                    |  | c. | Enable automatic switchover to the next available "slave" trunk if the device detects that the local-reference trunk is no longer capable of supplying the clock to the system: | 
                                            
                                            
                                                
                                                
                                                
                                                
                                                    |  | i. | From the 'TDM Bus PSTN Auto FallBack Clock' drop-down list (TDMBusPSTNAutoClockEnable), select Enable. | 
                                            
                                            
                                                
                                                
                                                
                                                
                                                    |  | ii. | From the 'TDM Bus PSTN Auto Clock Reverting' drop-down list (TDMBusPSTNAutoClockRevertingEnable), select Enable to enable the device to switch back to a previous trunk that returns to service if it has higher switchover priority. | 
                                            
                                            
                                                
                                                
                                                
                                                
                                                    |  | iii. | In the Trunk Settings page (see Configuring Trunk Settings), configure the priority level of the trunk for taking over as a local-reference trunk, using the 'Auto Clock Trunk Priority' parameter (AutoClockTrunkPriority). A value of 100 means that it never uses the trunk as local reference. | 
                                            
                                            
                                                
                                                
                                                
                                                
                                                    |  | 2. | (E1/T1 Trunks Only) Configure the PSTN trunk to recover/derive clock from/to the remote side of the PSTN trunk (i.e. clock slave or clock master): In the Trunk Settings page, configure the 'Clock Master' parameter (ClockMaster) to one of the following: | 
                                            
                                            
                                                
                                                
                                                
                                                
                                                    |  | ● | Recovered - to recover clock (i.e. slave) | 
                                            
                                            
                                                
                                                
                                                
                                                
                                                    |  | ● | Generated - to transmit clock (i.e. master) |